Most collapse incidents are compression failures, not contents failures. When someone asks "how strong is this box", the useful answer is the bottom-layer stacking capability.
| Metric | Measures | Unit |
|---|---|---|
| ECT (Edge Crush Test) | Board edge compression along the flutes | N/m or lb/in |
| BCT (Box Compression Test) | Finished box under vertical load | kg or N |
ECT tests the board; BCT tests the box. Box makers quote ECT values (e.g. "ECT 32"), but what you actually need is BCT.
McKee estimate: BCT ≈ 5.87 × ECT × √(perimeter × thickness) (ECT in N/m, dimensions in metres, result in N; divide by 9.8 for kg)
Worked example: 400×300×250mm C-flute box, board 4mm, ECT 5000 N/m, perimeter 1.4m: BCT ≈ 5.87 × 5000 × √(1.4 × 0.004) ≈ 2195 N ≈ 224 kg.
Layers = bottom BCT / (gross carton weight × safety factor)
| Scenario | Factor | Reason |
|---|---|---|
| Warehouse, ambient | 1.6 | Static load plus creep |
| Truck | 2.0 | Vibration and impact |
| Sea / cold store / humid | 2.2-2.5 | Moisture loss plus long duration |
Example: 224kg BCT with 12kg cartons: warehouse 224/(12×1.6) = 11 layers; same box by sea 224/(12×2.4) = 7 layers. Also check ceiling height and pallet rating - the answer is the smallest of the three.
Each 1% rise in board moisture costs roughly 5-8% compression; a humid warehouse (85% RH) runs 35-50% below dry-lab values, and sea containers lose strength for the whole voyage - hence the 2.2+ factor.
Creep under sustained load keeps eroding strength: about 65% retained after 30 days fully loaded, about 55% after 90 days. Plan long-term storage at roughly 0.65 × fresh BCT.
In short: the lab number is a new, dry, instantaneous number. Real stacking is old, damp and long.
Any serious box plant owns a compression tester; asking for BCT is standard practice, not an imposition.
| Gross weight | Stacking | Suggested build |
|---|---|---|
| ≤ 5kg | ≤ 3 layers | Three-ply E-flute (mailers) |
| 5-10kg | ≤ 5 layers | Three-ply B or C flute |
| 10-20kg | ≤ 5 layers | Three-ply C-flute, heavier liners (170g+) |
| 10-20kg | 6+ layers or sea | Five-ply BC double wall |
| 20-30kg | any | Five-ply BC or AB |
| > 30kg | any | Five-ply AB plus corner protection, or crate |
Treat the table as a starting point and confirm with measured BCT and the safety factor. Flute choice also fixes board thickness, which drives dimension compensation - set the flute first, then generate the dieline.