Home › Dieline Knowledge Base › How Much Can a Carton Hold and Stack: ECT, BCT and Layer Math

How Much Can a Carton Hold and Stack: ECT, BCT and Layer Math

Carton load bearing explained: how much a box holds versus how many layers it stacks, what ECT and BCT measure, the McKee formula for BCT from ECT, safety factors (warehouse 1.6, truck 2.0, sea 2.2), humidity and creep losses, and how to specify compression requirements to your box maker.
Short answer: Load bearing is two different questions: how much the box holds (paper weight and flute type) and how many layers it stacks (BCT box compression strength). Stacking layers = bottom-box BCT / (gross carton weight x safety factor), with safety factors of 1.6 for warehousing, 2.0 for trucking, 2.2-2.5 for sea freight. Estimate BCT from ECT with the McKee formula, BCT = 5.87 x ECT x sqrt(perimeter x thickness), but specify and verify real BCT measurements with your box maker.

Two different questions called load bearing

Most collapse incidents are compression failures, not contents failures. When someone asks "how strong is this box", the useful answer is the bottom-layer stacking capability.

ECT and BCT

MetricMeasuresUnit
ECT (Edge Crush Test)Board edge compression along the flutesN/m or lb/in
BCT (Box Compression Test)Finished box under vertical loadkg or N

ECT tests the board; BCT tests the box. Box makers quote ECT values (e.g. "ECT 32"), but what you actually need is BCT.

McKee estimate: BCT ≈ 5.87 × ECT × √(perimeter × thickness) (ECT in N/m, dimensions in metres, result in N; divide by 9.8 for kg)

Worked example: 400×300×250mm C-flute box, board 4mm, ECT 5000 N/m, perimeter 1.4m: BCT ≈ 5.87 × 5000 × √(1.4 × 0.004) ≈ 2195 N ≈ 224 kg.

Stacking layer math

Layers = bottom BCT / (gross carton weight × safety factor)

ScenarioFactorReason
Warehouse, ambient1.6Static load plus creep
Truck2.0Vibration and impact
Sea / cold store / humid2.2-2.5Moisture loss plus long duration

Example: 224kg BCT with 12kg cartons: warehouse 224/(12×1.6) = 11 layers; same box by sea 224/(12×2.4) = 7 layers. Also check ceiling height and pallet rating - the answer is the smallest of the three.

Two silent killers: humidity and time

Each 1% rise in board moisture costs roughly 5-8% compression; a humid warehouse (85% RH) runs 35-50% below dry-lab values, and sea containers lose strength for the whole voyage - hence the 2.2+ factor.

Creep under sustained load keeps eroding strength: about 65% retained after 30 days fully loaded, about 55% after 90 days. Plan long-term storage at roughly 0.65 × fresh BCT.

In short: the lab number is a new, dry, instantaneous number. Real stacking is old, damp and long.

Specifying compression requirements

  1. State the conditions: gross carton weight, stacking layers, transport mode;
  2. Ask for measured BCT in kg and the moisture at test;
  3. Ask for the safety-factor calculation for your layer count;
  4. Sample-test the first batch: 7-day full-load stacking, watch bottom-layer deflection.

Any serious box plant owns a compression tester; asking for BCT is standard practice, not an imposition.

Quick selection table

Gross weightStackingSuggested build
≤ 5kg≤ 3 layersThree-ply E-flute (mailers)
5-10kg≤ 5 layersThree-ply B or C flute
10-20kg≤ 5 layersThree-ply C-flute, heavier liners (170g+)
10-20kg6+ layers or seaFive-ply BC double wall
20-30kganyFive-ply BC or AB
> 30kganyFive-ply AB plus corner protection, or crate

Treat the table as a starting point and confirm with measured BCT and the safety factor. Flute choice also fixes board thickness, which drives dimension compensation - set the flute first, then generate the dieline.

Open the dieline generator →

Frequently asked questions

How much can a carton hold?
Contents capacity is mainly liner weight and flute type: a standard three-ply C-flute box carries 10-20kg; above 20kg move to five-ply BC. But holding is not stacking - compression is checked with BCT: layers = BCT / (gross weight x safety factor).
ECT versus BCT - what is the difference?
ECT is edge crush of the board (N/m); BCT is box compression of the finished box (kg) - BCT is what you need. McKee estimates BCT ≈ 5.87 x ECT x sqrt(perimeter x thickness), but specify measured BCT for engineering decisions.
How many layers can I stack?
Layers = bottom BCT / (gross carton weight x safety factor): 1.6 warehouse, 2.0 truck, 2.2-2.5 sea. Example: 224kg BCT with 12kg cartons = 11 layers in a warehouse, 7 at sea. Check ceiling height and pallet rating too.
Why do stacks collapse after a few days?
Humidity (5-8% compression lost per 1% board moisture; 35-50% in a humid warehouse) and creep (about 65% strength retained after 30 days loaded, 55% after 90). Plan long storage at roughly 65% of fresh BCT.
How do I specify compression to my box maker?
Give conditions (gross weight, layers, transport), request measured BCT in kg with test moisture, ask for the safety-factor calculation, and sample-test 7-day full-load stacking. Serious plants own compression testers.